• Moisture
  • Automatic Titration
  • Surface Science & Analysis
  • Liquid Density
  • Refractometer & Brix
  • Thermal
  • Liquid properties
  • Analytical Reference Standards
  • Particle Size
  • sieves
  • sieves / midpoint
Automatic Surface Tensiometer, DyneMaster DY-700
High-end surface tensiometer that performs measuring dynamic contact angle and powder contact angle, lamella length and liquid density in addition to surface/interfacial tension.

Features:
◆ Fully automatic operation by single command button
◆ Built-in stirrer functions in the stage
◆ Dynamic contact angle (advancing/receding angle) measurement by Wilhelmy method (Option of DY-700)
◆ Powder contact angle measurement to evaluate wetting phenomena of powder samples (Option of DY-700/500)
◆ Lamella length measurement
◆ Liquid density measurement by pycnometer

Typical applications:
• Dynamic contact angle for evaluating coating properties
• Powder contact angle for evaluating wettability, dispersiveness of powder sample
• Lamella length for evaluating foaming stability of coating agents

System Includes:
Main body built-in thermometer, jacket type stage, magnetic stirrer and built-in calibration system with Platinum plates (x2), Glass lab dishes for surface tension (x2), built in Level, Alcohol lamp, Forceps, and Operation manual.

Software Included:
• Main DYNALYZER Software for performing all basic operations including surface and interfacial tension tests.
• DYNALYZER add-in Powder measurement software
• DYNALYZER add-in Dynamic contact angle measurement software

Specifications:
• Measurement methods: Surface/Interfacial tension, Dynamic contact angle, Powder contact angle & wetting speed, Lamella length measurement, Liquid density measurement (Pycnometer)
• Measurement range of S.T.: 0~100 mN/m (balance capacity & displaying range: 0~1000mN/m
• Measurement accuracy: 0.02 mN/m
• Resolution: 0.01 mN/m
• Stage speed, stroke: 0.002~50 mm/s, 50mm
• Standard measurement unit: platinum plate
• Optional measurement unit & kit: Platinum DuNouy Ring, Density measurement kit, Dynamic contact angle measurement kit, Powder contact angle measurement kit
• Measurement temperature: Ambient ~ 150 degree C (Heater type), 10~70 degree C (jacket type)
• External Dimensions: 295(W) x 415(D) x452(H) mm
• Weight: about 23kg
• Electric power: AC100-240~50/60Hz
55,739.00 55739.0 USD
Automatic Surface Tensiometer, DyneMaster DY-500
DY-500 DyneMaster Automatic Tensiometer
High-end surface tensiometers that perform measuring dynamic contact angle and powder contact angle, lamella length and liquid density in addition to surface/interfacial tension (Wilhelmy plate or DuNouy Ring).

Features:
◆ Fully automatic operation by single command button.
◆ Built-in stirrer functions in the sample stage.
◆ Dynamic contact angle (advancing/receding angle) measurement by Wilhelmy method (Option of DY-700)
◆ Powder contact angle measurement to evaluate wetting phenomena of powder samples (Option of DY-700/500)
◆ Automatic Critical Micelle Concentration (CMC) of surface tension (Option of DY-700/500)
◆ Built-in surface thermometer (for heated/chilled samples requires electronic heater option or heater/chill bath option)
◆ Lamella length measurement
◆ Liquid density measurement by pycnometer

Measurement methods:
• Surface/interfacial tension
• Powder contact angle & wetting speed
• Lamella length measurement,
• Liquid density measurement (Pycnometer)

Specifications:
• Measurement range of S.T.: 0~100 mN/m *Balance capacity & displaying range: 0~1000mN/m
• Measurement accuracy*: 0.2 mN/m
• Resolution: 0.01 mN/m
• Stage speed, stroke: 0.002~50 mm/s, 50mm
• Standard measurement unit: Platinum plate or Platinum DuNouy Ring
• Optional measurement unit & kit: Platinum ring, Density measurement kit, Dynamic contact angle measurement kit, Powder contact angle measurement kit, CMC Kit
• Measurement temperature: Ambient~150°C (Heater type), 10~70°C (Jacket type)
• External dimensions: 295(W) x 415(D) x 452(H)mm
• Weight: About 20kg
• Electric power: AC100-240~50/60Hz
43,555.00 43555.0 USD
DCA 200A Dynamic Contact Angle and Surface Tension Analyzer (All In One)
All in one Dynamic contact angle and Surface tension Analyzer
- Auto close outer wall, Ergonomic, user friendly design
- Able to density data of liquid by underwater displacement
- Fully automatic measuring process (Software control)
- Internal thermo couple for checking test liquid’s temperature
- Basic Supporting Items: (1) Zisman plots (2) Surface Energy calculation (3) Surface Tension(DuNouy Ring & Willhelmy Plate & Rod method) (4) Dynamic contact angle (5) Density (6) Sedimentation (7) Penetration (8) Powder contact angle (9) Absorption (10) Single fiber contact angle (11) Bundle fiber contact angle
- Results data can export to excel
- Circulator connection port
- Displaying entire measuring process
- Internal Circulation chamber
- Calibration function
26,895.00 26895.0 USD
Evaporator for Ores
ADP-512 High Heat Evaporator for Ores for Karl Fischer

[Features]
1) Measurement for micro amount of water is least affected from ambient moisture because the movement of
sample boat is controlled by magnet, operated outside the sealed heating unit, and thus accurate and reliable
results are assured.
2) The newly designed electric furnace operates in a wide range of degrees from room temperature up to 1000°C,
featuring relatively short warm-up time, taking approximately 30 minutes for temperature rise as well as for
equilibrium respectively.
3) PID control by the built-in thermostat provides an accurate and stable oven temperature.
4) The safety while working on the electric oven is secured because the maximum temperature over the oven
surface is always kept under 70°C.
5) The built-in excessive heat prevention unit is another safety measures with a thermometer in it, which is
separate from the sensor for temperature control.
6) This evaporator is equipped with two types of electric furnace (for low temperature and for high temperature),
which enables measurement for hygroscopic water as well as combined water without taking the sample out
of the oven.
24,000.00 24000.0 USD
DSR 500 CP 4000 Plus Rheometer + CYL Air Peltier (+10°C to +70°C) with Programmer
INCLUDES:
• Temperature unit with 70mm bottom plate.
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES
Automatic lift for gap • Quick attachment with AC265 coupling • Direct curve on display • Shear rate and speed control • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $23,611.00
23,611.00 23611.0 USD
DSR 500 CP 4000 Plus Rheometer Air-Air Peltier (0°C - 150°C) with Programmer
INCLUDES:
• Temperature unit with 70mm bottom plate.
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES: Automatic lift for gap • Quick attachment with AC265 coupling • Direct curve on display • Shear rate and speed control • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $22,485.00
22,485.00 22485.0 USD
DSR 500 CP 4000 Plus Rheometer Air-Air Peltier (0°C - 150°C)
INCLUDES:
• Temperature unit with 70mm bottom plate.
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES
Automatic lift for gap • Quick attachment with AC265 coupling • Direct curve on display • Shear rate and speed control • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $21,633.00
21,633.00 21633.0 USD
DSR500 CP4000 PLUS RHEOMETER + LIQUID PELTIER (-20°C TO +100°C) with PROGRAMMER
FEATURES
• Flow ramp method with data analysis according rheological models.
• AC265 coupling for quick connection of spindle.
• For using with spindle MS-CP and MS-PP. Motorised adjusting of gap.
• USB port for data transfer or printer. USB and serial port for software
connection.
• Programmer for temperature ramp.
• Cooling/ heating by liquid Peltier from -20°C to +100°C (needs circulating bath not included).

REQUIRES CHILLER FOR OPERATION. NOT INCLUDED.

REGULAR PRICE: $21,606.00
21,606.00 21606.0 USD
DSR 500 CP 4000 PLUS RHEOMETER AIR PELTIER (+10°C to +70°C) with PROGRAMMER
INCLUDES:
• Temperature unit with 70mm bottom plate
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Automatic lift for gap • Quick attachment with AC265 coupling • Direct curve on display • Shear rate and speed control • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $21,604.00
21,604.00 21604.0 USD
DSR 500 CP 4000 Plus Rheometer Air-Air Peltier (10-70°C)
INCLUDES:
• Temperature unit with 70mm bottom plate.
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES
Automatic lift for gap • Quick attachment with AC265 coupling • Direct curve on display • Shear rate and speed control • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $20,755.00
20,755.00 20755.0 USD
DST-100A
- User-friendly design
- Density data of liquid by underwater displacement
- Automatic measuring process (software control)
- Basic supporting functions
1) Surface Tension (DuNouy Ring & Willhelmy method)
- Results data can be exported to Excel
- Circulator connection port
- Displays the entire measuring process
- Internal circulation chamber
- Calibration function

Includes:
(1) Zisman plot
(2) Surface energy calculation
(3) Dynamic contact angle
(4) Density
(5) Sedimentation
(6) Penetration
(7) Powder contact angle
(8) Absorption
(9) Single fiber contact angle
(10) Bundle fiber contact angle

Specifications:
- Methods: DuNouy Ring / Wilhelmy Plate
- Measuring range: 1 to 2,000 dynes/cm (mN/m)
- Accuracy: +/-0.1 dynes/cm (mN/m)
- Balance Capacity: 250 grams
- Liquid Vessel: Glass Container
- Power Supply: 100-220V
- Dimensions: 9 x 12 x 21 in
- Weight: 15kg
20,709.00 20709.0 USD
DCA-200S Dynamic Contact Angle and Surface Tension Analyzer
Dynamic contact angle and surface tension analyzer (Standard type)
- Auto close outer wall, Ergonomic, user friendly design
- Able to density data of liquid by underwater displacement
- Fully automatic measuring process (Software control)
- Internal thermo couple for checking test liquid’s temperature
- Basic Supporting Items: (1) Zisman plots (2) Surface Energy calculation (3) Surface Tension(DuNouy Ring & Willhelmy Plate & Rod method) (4) Dynamic contact angle
- Results data can export to excel
- Circulator connection port
- Displaying entire measuring process
- Internal Circulation chamber
- Calibration function
20,509.00 20509.0 USD
Density/Specific Gravity Meter (860)
Density/Specific Gravity Meter
ASTM D1250,D1475,D4052,D4806,D5002,D5798,D5931

-DI Support Feature as Standard
-Simultaneous multiple measurements
-Remote operation by a separated control terminal
-Improvement of the measurement cell visibility with a built-in camera

Configuration:
1. DA-860 main unit
2. Pump & Sampling unit type = 120799701/Sampling Unit with Accessories (Semiautomatic with 2 liquids)
3. Decoration panel = Stripe
4. Printer (mini) is NOT INCLUDED
5. Requires a computer (laptop or Surface Pro) = NOT INCLUDED
< Desktop/Laptop PC Spec >
OS.................................Windows® 10 Pro 64 bit
CPU..............................> = Core i3 10th Generation
Memory........................> = 8GB
HDD or SSD..................> = 300GB
Display Resolution.......> = 1280 x 768
Interface(LAN / USB)...> = 1000Mbps
< Tablet PC Spec >
OS.................................Windows® 10 Pro 64 bit
CPU.............................. > = Intel® Pentium® Gold 4425Y
Memory........................> = 4GB
HDD or SSD..................> = 64GB
Display Resolution.......> = 1280 x 768
Interface(LAN / USB)...> = USB3.0 x 1ch

Specifications:
-Measurement Method; Resonate Frequency Oscillation
-Measurement Range; 0 ~ 3 g/cm3
-Temperature Range; 0 ~ 100°C (32 ~ 212°F)
-Accuracy; Density; 0.00002
-Accuracy; Temperature; ±0.02
-Repeatability; SD 0.000001g/cm3
-Viscosity Correction: YES
-Min sample required; Approx. 1.0mL (by syringe), Approx. 2.0mL (by pump)
-Min Measurement Time; 1) Approx. 10 seconds (Manual) *4
-Display;
1) Tablet / PC connection (LCD resolution: 1,280 x 800 or higher)
2) Shows density, SG, oscillation frequency, temp, concentration, other messages.
-Sampling;
1) Manual by syringe
2) Auto by pump
-Method; Saves up to 1000 different methods in built-in memory including measurement parameters, density auto-correction, concentration conversion, etc.
-Density Auto-Correction;
1) Saves conversion table or formula at your desired temperatures according to your samples.
2) Temperature conversion table preprogrammed according to ASTM standard for petroleum, petroleum products and lubricating oils.
-Auto Conversion;
1) Between concentration and density.
2) Between temperature and density.
-Statistics;
1) Auto or manual calculation of mean value, SD and coefficient.
2) Recalculation, data deletion.
-Interfaces;
1) LAN: × 1; Tablet / Personal computer (PC)
2) USB 2.0: × 1; USB flash drive, Thermal Printer (DP-600)*5
3) RS-232C: × 2; Dot Matrix Printer (IDP-100)*4, Autosampler (AS-8030)
-Options;
1) Printer: DP-600, IDP-100
2) 30 Position Autosampler: AS-8030
-Data I/O;
1) USB flash drive as data storage medium.
2) Application Notes provided in USB flash drive.
-Wetted Materials; PTFE, borosilicate glass, SUS304
-Ambient Condition;
1) Temperature: 5 to 35 °C (41 to 95 °F)
2) Humidity: 85%RH or below (No condensation allowed.)
-Power Supply; DC 24V 5A (Main Unit) AC 100 to 240 V ± 10%; 50/60 Hz (Comes with AC adapter.)
-Power Consumption; 40 W (max. 120 W, min. 20 W)
-Dimensions; 295 (W) × 330 (D) × 255 (H) mm (11.6 (W) × 13.0 (D) × 10.0 (H) inches)
-Weight; 19 kg (41 lbs)

20,320.00 20320.0 USD
RM 200 CP4000 PLUS RHEOMETER AIR PELTIER (0 °C to +150°C) WITH PROGRAMMER
Includes:
• Temperature unit with 70mm bottom plate
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES: • Automatic lift for gap • Quick attachment with AC265 coupling • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Speed or shear rate control • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $19,929.00
19,929.00 19929.0 USD
RM200 CP4000 PLUS RHEOMETER LIQUID PELTIER (-20°C to +100°C) with PROGRAMMER
FEATURES
• Flow ramp method with data analysis according rheological models.
• AC265 coupling for quick connection of spindle.
• For use with spindle MS-CP and MS-PP. Motorised adjusting of gap.
• USB port for data transfer or printer. USB and serial port for software
connection.
• Programmer for temperature ramp.
• Cooling/ heating by liquid Peltier from -20°C to +100°C (needs
circulating bath not included).

REGULAR PRICE: $19,048.00
19,048.00 19048.0 USD
RM200 CP4000 PLUS RHEOMETER AIR PELTIER (+10°C to +70°C) with PROGRAMMER
INCLUDES:
• Temperature unit with 70mm bottom plate
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES: • Automatic lift for gap • Quick attachment with AC265 coupling • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Speed or shear rate control • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $19,048.00
19,048.00 19048.0 USD
KCHD-502H Multiple Sample Changer w/Heat Option
CHD-502H Multiple Sample Changer with a w/Heating Option and integrated DCU-551 auto cleaning and sampling unit.

The CHD-502 multiple sample changer is used in combination with the density meter DA-600 series. A maximum of 30 samples in each 20mL vial can be set on a carousel. This sampler provides when connected to a density meter a series of events in sequence including cleaning and drying the sample line up to the measuring cell.

H-Type: For the measurements on a sample with a higher softening point, both the turntable unit and the sampling path can be heated and kept warm – the H-type option for heating the turntable unit with an electric heater up to 80°C.

Features:
- Adoption of a peristaltic pump allows an operator to measure the density on a higher viscous sample of 30,000 mPa•s
- The sequential program automatically stops when the unit detects an empty vial position after the last sample vial is finished.
- This unit is equipped with a self-diagnostic function by checking the sequence program, keypad function, and display.
- The auto-power off functions when a series of measurements is finished so that it saves electricity when operated overnight unattended. This feature can be set in while the unit is being activated.
- The cleaning efficiency is increased by blending air into the rinse solvent. By this way, the total amount of rinse solvent is decreased and saved. In addition, not only inside but outside of the nozzle can be cleaned very well since the rinse solution is fed from the outside of the nozzle unit.
- Expensive sample materials like perfume or fragrance can be returned back to sample vial after measurement are over.
-This unit is conformed to CE-mark for safety and noise regulation.

Specifications:
- Number of vials: Up to 30 (20mL vials)
- Minimum sample required: 10mL
- Sample position: Turntable system
- Sampling method: Pressurizing by Peristaltic pump
- Setting Temperature: Room Temp. ~ 80°C
- Heating and cooling system: By electric heater
- Drain System: Sample-returning to vial system

- Program Sequence:
1) Sample measurement only
2) Sample measurement after the "Air & Water" calibration
3) Sample measurement after the "Two kinds of Standard liquids" calibration

-Control:
1) Auto-start by [Meas.] key of density / specific gravity meter or concentration meter
2) Auto-start by [Start.] key of CHD-502 unit
3) Rinsing and purging
4) Auto-calibration by [Calib.] key of density / specific gravity meter or concentration meter
5) Priority measurement

-Display: 20 digits by 2 lines LCD with a backlight

-External communication:
1) Simplified serial interface via the connecting cable (980303388)
2) RS-232C interface for communications

-Ambient Temperature: 1) Temperature: 5 ~ 35°C ; 2) Humidity: less than 85%RH (No condensation)
-Power consumption: Max.760W (NRP40W)
-Dimensions: 582(W) x 445(D) x 392(H) mm
-Weight: Approx. 17kg
19,000.00 19000.0 USD
RM 200 CP-4000 PLUS RHEOMETER WITH AIR PELTIER (+10°C TO +70°C)
INCLUDES:
• Temperature unit with 70mm bottom plate
• Touch screen stylus.
• User manual.
• Calibration and checking certificate.
• Microfiber cloth.

FEATURES: • Automatic lift for gap • Quick attachment with AC265 coupling • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Speed or shear rate control • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $18,198.00
18,198.00 18198.0 USD
Automatic Surface Tensiometer, DyneMaster DY-300
This instrument is specified for determining interfacial tension of oil against water by the ring method in ASTM Method D971 and solutionsof surface-active agents in ASTM Method D1331. It is also specified for testing synthetic rubber lattices in ASTM Method D1417 and determing the surface tension of industrial water and industrial wastewater in ASTM Method D1590 (To name a few).

Main unit (laptop PC not included), software provided on CD, Platinum plates or DuNouy Ring (choose 2), Glass lab dishes for surface tension (x2), Calibration weights (200mg x2), built in Level, Alcohol lamp, Forceps, and operation manual.

Features:
◆ ­Fully automatic operation by single command button
◆ For QC use, repetition of measurement can be preset
­◆ For surface solutions, graph of variations over time can be plotted
­◆ For R&D use, functions of graph overwriting and data converting to a spreadsheet can be prepared
­◆ Measurements of lamella length and liquid density are available in addition to surface/interfacial tension

Screens:
• ­Surface Tension (static mode)
­• Surface Tension (dynamic variations over time)
­• Surface Tension (high viscous material)
­• Lamella Length

Applications:
• ­Surface Tension: evaluating detergency of detergents, wettability of coating agents
­• Interfacial Tension: evaluating emulsification property of water/oil
­• Lamella Length: evaluating foaming stability of coating agents
• Liquid Density: measuring density of liquids

Specifications:
• Measurement Method: Wilhelmy Plate method and or DuNouy Ring method
­• Measurement Range: 0~100 mN/m *Balance capacity and displaying range 0~1000 mN/m
• ­Measurement Accuracy: 0.2 mN/m
­• Resolution: 0.01 mN/m
• ­Stage Speed: 0.1~1 mm/s
­• Measurement Temperature: Ambient~150 degrees C (Heater type stage system)10~70 degrees C (Jacket type stage set with hot/cold water circulator 4VT)
• Software: Standard: Surface/Interfacial tension, Lamella length, Liquid density
• Detecting Parts: Standard: Platinum plate
• Option: Platinum ring, Pycnometer for density, Accessory for sedimentation
­• External Dimensions: 255(W)x307(D)x369(H) mm
• ­Weight: about 12.5kg
­• Electric power: AC100­240~50/60Hz 35W 75VA
17,200.00 17200.0 USD
GT300 PRODIG GEL TIMER (Room T°C to +300°C) with Programmer
INCLUDES:
• Holder for disposable hook
• Integrated temperature unit
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

REGULAR PRICE: $17,007.00
17,007.00 17007.0 USD