• Karl Fischer
  • Water Activity
  • Loss on Drying
Evaporator for Ores
ADP-512 High Heat Evaporator for Ores for Karl Fischer

[Features]
1) Measurement for micro amount of water is least affected from ambient moisture because the movement of
sample boat is controlled by magnet, operated outside the sealed heating unit, and thus accurate and reliable
results are assured.
2) The newly designed electric furnace operates in a wide range of degrees from room temperature up to 1000°C,
featuring relatively short warm-up time, taking approximately 30 minutes for temperature rise as well as for
equilibrium respectively.
3) PID control by the built-in thermostat provides an accurate and stable oven temperature.
4) The safety while working on the electric oven is secured because the maximum temperature over the oven
surface is always kept under 70°C.
5) The built-in excessive heat prevention unit is another safety measures with a thermometer in it, which is
separate from the sensor for temperature control.
6) This evaporator is equipped with two types of electric furnace (for low temperature and for high temperature),
which enables measurement for hygroscopic water as well as combined water without taking the sample out
of the oven.
24,000.00 24000.0 USD
Evaporator (KF-610 series)
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
8,800.00 8800.0 USD
Evaporator (for Karl Fischer testing heavy Oil)
ADP-513 Karl Fischer Oil Evaporator

FEATURES:
-Digital temperature control
-Rotameter carrier gas flow control
-Built-in carrier gas drying system Operating temperature ambient up to 200°C Heated transfer tube
-Overheating protection
-Automatic cell evacuation system

SPECIFICATIONS:
Temperature Range: Room - 200°C
Heating method: Cartridge base heater
Ambient conditions: 5 - 35°C, less than 85% RH
Power: AC100~120/200~240V±10%)(Specify required voltage)
Power Consumption: 400W
Dimensions: 320 x 210 x 330 mm
Weight: Approx. 6 kg
8,550.00 8550.0 USD
Coulometric Karl Fischer Titrator
-Measuring Range; Water content / Bromine index: 10ug to 300mg
-Measurement cell; 2-Component or 1-Component
-Precision; Relative standard deviation : less than 0.3% (n=10) *Per KEM standard measurement conditions and standard liquids
-Display resolution; 0.1ug
-Methods; 20
-Data storage; 100 samples
-External I/O; -232C port × 2 (for printer, balance, software), USBx1 (for USB flash drive, printer, keyboard, barcode reader, foot switch, USB hub, Android device)
-Ambient Condition; (1) Temperature: 5 to 35°C (2): 85% H or below (no condensation)
-Power Source; AC100 - 240 ±10% 50/60 Hz
-Dimensions; 141(W ) × 292(D) × 244(H) mm
-Weight; Approx.3.0kg
-GLP Conformance; Registration of operator / Check performance with standard substance / reagent life control / Management of conduction time
-Conformity Standard; CE marking EMC: EN61326-1 L D: EN61010-1
8,075.00 8075.0 USD
Aquapal III Moisture Analyzer w/ Standard Glassware
Aquapal III Moisture Analyzer W/ Standard Glassware:
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved Manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm -% - ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
7,990.00 7990.0 USD
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
Aquapal III Moisture Analyzer W/ Single Reagent Glassware: Coulometric Titrator Diaphramless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved Manufacturer. unit ready for operation, includes: - Built in printer with standard paper that backs up test with hard copy results. - Speed is 2 mg/minute - Test range from 1ppm to 100% - Sensitive to 0.1 ug - Calculations in Weight, volume or dilution - Automatic Drift Correction - Results printed in ppm ,% , ug - Standard RS232C output - Small lab foot print 14" x 8" - Portable (field Use) *Easy to use for non-technical operators - Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will printout automatically.
7,990.00 7990.0 USD
Volumetric Karl Fischer Titrator
MKV-710B Volumetric Karl Fisher Titrator

Specifications:
-Type: Volumetric Karl Fischer Moisture Titrator

-Model: MKV-710B

-Product configuration: MKV-710+ Manual Solvent Change Unit.

-Measuring method: Karl Fischer Volumetric Titration

-Measuring range:
1. Water content: 0.1 to 500mgH2O (depends on KF reagent factor)
2. 10ppm to 100%H2O

-Burette precision: Volume: 10mL burette, Discharge precision: ±0.015mL repeatability, Repeatability: ±0.005mL

-Endpoint detection: By polarized potential level detected with a twin platinum electrode

-Titration form: Normal titration / Back titration (Option additional burette required)

-Required solvent: 30 to100mL (in S-type titration vessel)

-Methods: 20

-Key Operation: Sheet key on main unit

-Display:
1. White LED-backlit LCD
2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish
3. 1-channel display

-Calculation: Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value

-Data storage: 100 samples

-GLP conformance: 􏰄registration of operator / 􏰅Record of check results/ Record of factor measurement / Management of conduction time

-External I/O:
1. RS232C port × 2 (for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP)
2. USB x 1 (for USB flash drive, thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB, Android device)
3. SS-BUS x 1 (for APB)

-Extensibility
1. Automatic piston burette: Can control max 2 burette drives (including two built-in burette drives)

-Ambient Condition:
1. Temperature; 5 to 35°C
2. Humidity; 85%RH or below (no condensation)

-Power Source: AC100 - 240 ±10% 50/60 Hz

-Power Consumption: Main unit; Approx. 20W, Printer; Approx. 7W

-Dimensions:
1. Titration Unit; 141(W) × 292(D) × 367(H) mm (, not incl. tubing)
2. Stirrer; 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
3. Solvent Change Unit; 240(W) × 140(D) × 400(H) mm (not incl. tubing)
4. Printer; 106(W)× 180(D) × 88(H) mm

-Weight:
1. Titration Unit = 4.0kg,
2. Stirrer = 2.0kg,
3. Solvent Change Unit = 0.6kg,
4. Printer = 0.4kg

-Conformity Standard: CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
7,850.00 7850.0 USD
Touch Panel Controller
MCU-610 Touch Panel Controller for Titrator
7,457.00 7457.0 USD
4,312.00 4312.0 USD
Standard Glassware, Complete Set and Accessories
Standard Glassware, Complete Set And Accessories includes:
-26100SIV: Aquapal Molecular Sieve (bottle)
-26100VES: Titration Vessel with caps and seals
-26100DEL: Detector Electrode
-26100GEL: Generator Electrode (with Frit)
-26100ODT: Drying Tube with cap
-26100BAR: Stirrer Bar
-26100NEE: Needle / 4 inch
-26102SYP: 5 each disposable syringes
-26100SEP: Pack of 50 each Injection Septa
-26100FUN: Funnel
3,440.00 3440.0 USD
Single Glassware, Complete Set and Accessories
Single Glassware Setup, Complete Set And Accessories includes: 26100SIV: Aquapal Molecular Sieve (bottle) 26100VES: Titration Vessel with caps and seals 26100DEL: Detector Electrode 26100GEL: Generator Electrode (without Frit) 26100ODT: Drying Tube with cap 26100BAR: Stirrer Bar 26100NEE: Needle / 4 in 26102SYP: 5 each disposable syringes 26100SEP: Pack of 50each Injection Septas 26100FUN: Funnel
3,440.00 3440.0 USD
Liquefied gas sampler/MKC
K433-3389: Liquefied gas sampler/MKC, MKA

Parts Included:
(1) Connecting pipe12-05241
(2) Needle 66-00196
(3) Sampling cock 12-05144
(4) Exhaust tube 􏰓 Desiccator 12-04306 (not for MKC)
(5) Bubbler 20-09225
(6) Bubbler adapter 20-09226 (not for MKA)
(7) Stopper with septum 98-433-0062
(8) PTFE Packing 20-05723
(9) Stand, Clamp, Clamp holder 98-433-0063
(10) Desiccant Container 12-05333 (not for MKA)
(11) Silicone grease 12-04181
(12) Liquefied gas sampler Operation Manual 59-00427
3,345.52 3345.52 USD
1Component Type Titration Cell Unit with Funnel
1Component Type Titration Cell Unit with Funnel
3,297.72 3297.7200000000003 USD
2Component Type Titration Cell Unit
K120735501(12-006-6100-48) (K433-0005): Karl Fisher Cell Unit; For two solution system; Includes Titration cell, Inner burette (2-solution), Twin Platinum detector electrode, Port Plugs, Stir Bar, Pack of septa, and Desiccant Tube A.
3,248.00 3248.0 USD
1Component Type Titration cell unit
Titration cell unit complete with 1component inner burette, detector electrode, port plug, and stir bar
3,245.00 3245.0 USD
Liquefied gas sampler/MKA
K433-3014: Liquefied gas sampler/MKA
3,106.55 3106.55 USD
Heat Extractor for Sugar Samples
ADP-344; Heat Extractor for Sugar Samples
2,985.00 2985.0 USD
Homogenizer attachment
K433-0085: Homogenizer attachment
2,927.33 2927.33 USD
A&D HR-250AZ Analytical Balance

A&D HR-250A Analytical Balance:
-Capacity: 252g
-Readability: 0.1mg
-Minimum weight: 140mg
-Linearity: +-0.3mg
-Stabilization time: Approx. 2 seconds
-Internal calibration: YES
-Display type: Reverse backlit LCD
-Interface: RS232
-External dimension: 198(W) x 294 (D) x 315 (H) mm
-Net weight: Approx. 3.9kg
-Power Supply: AC adapter

- Compact Super Hybrid Sensor (C-SHS) technology - enables you to perform high-speed, frustration-free weighing even at a readability of 0.1 mg.
- Built-in calibration mass - lets you ensure the accuracy of your balance with just one key press.
- Compact footprint: 198 mm × 294 mm - With the C-SHS, the footprint of the balance is smaller than the ISO A4 (210 mm × 297 mm) paper size, maximizing opportunities for the use of an analytical balance in even the smallest of spaces.
- Rotary sliding doors - Unlike conventional analytical balances, the HR-AZ/HR-A series requires no extra space at the rear for accessing the weighing chamber, as the doors simply rotate behind the balance.
- Removable breeze break - The breeze break is easily removed using a unique clip system, allowing fast, simple cleaning and use in confined spaces like gloveboxes and controlled environment cabinets.
- Lean design for affordability - The HR-AZ/HR-A design is all about “keeping it simple” without compromising quality or performance. This is a compact, precise, and reliable analytical balance for the value-conscious user.
- GLP/GMP/GCP/ISO compliant output - For compliance and documentation requirements, the HR-AZ/HR-A series can output the balance manufacturer, model, serial number, ID number, date and time*1, space for signature, and calibration records.
- User access control (UAC) with password function - The balance can be password-protected to allow only authorized individuals to use it or change its settings. It is also possible to disable any change to the balance settings including calibration or, for HR-AZ models, correction of the internal mass value.
- Adjustable response characteristics and hold function - From three preset combinations of weighing speed and stability (FAST, MID, or SLOW), select the one that best suits your environmental conditions (drafts and vibrations). A hold function is also available for weighing animals.
- Statistical calculation function - The balance displays and outputs statistical calculation data including number of data, sum, maximum, minimum, range (maximum–minimum), average, standard deviation, and coefficient of variation.
2,715.00 2715.0 USD
2,667.00 2667.0 USD