• Moisture
  • Automatic Titration
  • Liquid Density
  • Refractometer & Brix
  • Thermal
  • Liquid properties
GT 300 Plus Gel Timer (No Temperature Control)
The GT300 Gel Timer measures curing time of your product.

INCLUDES:
• RheoTex software
• Holder for disposable hook
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Measure with disposable hooks and cups • Low sample volume • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $11,542.00
11,542.00 11542.0 USD
KDCU-551N Auto Cleaning and Sampling Unit
KDCU-551N Auto Cleaning and Sampling Unit
10,847.00 10847.0 USD
Phoenix-MT (M) Contact Angle Analyzer
-Camera capture speed: 640x480resolution 500FPS (USB 3.0)

-Static Contact Angle (Tangent line method 1 & 2, Trigonometric function):
Accuracy; ±0.1degree
Resolution; ±0.01degree
Range; 0~180°
Data Information; Average contact angle, left contact angle, right contact angle, drop
volume, height, baseline length, base area, measured time, wetting energy, spreading
coefficient, work of adhesion

-Dynamic Contact Angle: Tilting method (OPTIONAL)
Accuracy; ±0.1degree
Resolution; ±0.01degree
Range; 0~90°
Data Information; Work of adhesion, Advance angle, Receding angle, Hysteresis,
drop volume, etc.,

-Surface Tension: Pendant drop method
Accuracy; ±0.1mN/m
Resolution; ±0.01mN/m
Range; 1~1000mN/m
Data Information; Drop volume, Surface tension

-Surface Free Energy:
(A) G.G.F.Y: (Accuracy ±0.1mN/m) (Resolution ±0.01mN/m) (Data Information,
Surface free Energy)
(B) Owens-Wendt (Accuracy ±0.1mN/m) (Resolution ±0.01mN/m) (Data
Information, Surface free energy, Dispersive value and Polar value)
(C) Lewis[Acid/Base] (Accuracy ±0.1mN/m) (Resolution ±0.01mN/m) (Data Information, Surface free Energy, Dispersive, Polar, Acid, base value

-Capture Speed: CCD, (Range 0~500FPS) (Data Information, Basic supplied is 500FPS)

-Machine Vision Resolution: (Range 640x480) (Data Information, Basic supplied is 640x480)

-Data Export Method: Two modes of Excel export, BMP, CSV file

-Data Save Method: Save as .SZX and Excel

-Sample Stage: Fixed Stage (no movement on X,Y axis)

-Device Dimension: Comes with Standard size (small and custom size is available)

-Power Consumption: 1.LED : 8.64W

-Power: 110/220V(50/60HZ)
10,708.00 10708.0 USD
Kit for Titanium Probes
Kit for Titanium Probe
-Factory option
-For samples with strong acidity or alkalinity that generally corrode aluminum spheres
-Includes 50 sets; sample containers (vials) 13mm + Titanium 5mm probes
10,667.00 10667.0 USD
Kit for Small Volume Measurment (90uL)
Optional Kit for Small Volume Measurment (90uL) / EMS-1000S
-Factory option
-For measurement with smaller samples , 90uL
-Includes Uniform heating block, hook holder, 100 sets of sample containers, 8mm with cap, 50 sets aluminum probes, 2mm
10,667.00 10667.0 USD
Refractometer
RA-620 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.58000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.00002,Brix=±0.014%(0~85%)
-Repeatability *2:Refractive Index (nD)=±0.00001,Brix=±0.01%
-Resolution:Refractive Index (nD)=0.00001,Brix=0.01%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.01°C
-Minimum Amount of Sample: 0.2mL
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
10,550.00 10550.0 USD
KEM Sample Changer, 12 Samples
KCHG-310-12: KEM Sample Changer, 12 Samples
10,150.00 10150.0 USD
11 Position Sample Changer
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
9,900.00 9900.0 USD
RM 100 i IMMERSION INDUSTRIAL VISCOMETER WITH PT100 SENSOR
Included:
• 2m cable between measuring head and box
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: • Industrial measure on large tanker • Continuous measurement or with time to stop • 4-20 mA output for external control • 17m maximum distance between head and box • Usable with standard or rack stand • Huge viscosity range • Programming and recording methods • External temperature probe (option) • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $9,767.00
9,767.00 9767.0 USD
VariSifter Sonic Separator
The next generation sonic sifter. The VariSifter is a top-of-the-line particle separator that generates the same repeatable and reproducible results as with the original L3P Sonic Separator but with upgraded features including adjustable frequency, multiple built-in tapping options, touch screen and a universal power converter.
Includes: Complete stack assembly and instruction manual.
Uses 3” clear acrylic sieves (sold separately).
9,532.00 9532.0 USD
RM 100 i IMMERSION INDUSTRIAL VISCOMETER
INCLUDES:
• 2m cable between measuring head and box
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: • Industrial measure on large tanker • Continuous measurement or with time to stop • 4-20 mA output for external control • 17m maximum distance between head and box • Usable with standard or rack stand • Huge viscosity range • Programming and recording methods • External temperature probe (option) • Printer connection • Display of viscosity limits according to spindle and speed

REGULAR PRICE: $9,402.00
9,402.00 9402.0 USD
Refractometer
RA-600 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.7000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Repeatability *2:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Resolution:Refractive Index (nD)=0.0001,Brix=0.10%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.1°C
-Minimum Amount of Sample
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
8,990.00 8990.0 USD
Evaporator (KF-610 series)
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
8,800.00 8800.0 USD
Automatic Titrator (with standard preamp)
KEM AT­-710B Automatic Potentiometric Titrator with Standard Preamp.

Specifications
­Type: Automatic Potentiometric Titrator

­Model: AT­710B

­Product configuration: AT­710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)

­Detection range:
1) Potentiometric : ­2000mV to +2000mV
2) pH : ­20.000 to 20.00pH
3) Temperature : 0 to 100°C

­Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
­Method: Standard method 20. (Max 2 methods can be linked)

­Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity

­Titration form: Full titration (Auto EP detection), EP Stop, Level Stop

­Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)

­Key operation: Sheet Key on the main unit

­Displays:
1) White LED­backlit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1­channel display

­Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value

­Data Storage: 50 samples

­GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time

­Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL

­Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL

­External I/O:
RS­232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFT­CAP)
SS­BUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device

­Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
built­in burette drives)
Multiple sample changer: CHA­700 series

­Ambient condition:

1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)

­Power source: AC100 ­ 240V ±10% 50/60 Hz
­Power consumption: 20W

­Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm

­Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg

­Conformity standard: CE marking EMC: EN61326­1 LVD: EN61010­1 RE
Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
8,500.00 8500.0 USD
6 Position Sample Changer
CHA-700 : Automatic Titrator Multiple Sample Changer

1)Compact Design; This changer can be placed on top of the AT-700/710. You will see how compact it is: equipment width – 365mm.
2)Six-rack Model or Eleven-rack Model; Six racks for samples plus one more rack for immersion cleaning. Holds beakers of 250mL or 200mL.
Eleven-rack model: Holds containers of φ46mm, such as 50mL beakers or 100mL disposable cups.
3) Optional Electrode Cleaning Available; Optional electrode cleaning system can be connected for shower cleaning of electrodes. Furthermore, for six-rack model, shower cleaning (nonaqueous) of electrodes and drain samples from the beaker is available.
4) Different Measurement Methods from One Rack to Another; Individual settings can be made for each rack, which enables you to easily perform measurements of several different
samples.

-Sample Container options; 250mL beaker, 200mL disposable cup, 250mL beaker or 200mL beaker. Additional options include;
100mL disposable cup, 50mL beaker, 100mL beaker or 100mL tall beaker
-Cleaning; Dipping in beaker at fixed position / Shower cleaning (option)
-Rinse Solution; Pure water , alcohol, etc.
-Stirring Device; Propeller stirrer
-Sequence setting; Set from Automatic Potentiometric Titrator
-Sequence control; 1)Auto : started by Automatic Potentiometric Titrator / 2)Manual : operated from Automatic Potentiometric Titrator
-Power Supply; DC24V 1.9A(Main unit) AC100-240V 10% 50/60 Hz(Comes with AC Adapter)
-Dimensions; 365 (W) × 443(D) × 315 (H) mm
-Weight; Approx. 8kg
-CE Marking; EMC : EN61326 / LVD : Conforming to EN61010-1
8,500.00 8500.0 USD
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
Coulometric Titrator Diaphragmless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved manufacturer.
Unit ready for operation. Includes:
- Built in printer with standard paper that backs up test with hard copy results.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm ,% , ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
- Easy to use for non-technical operators
- Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will print out automatically.
8,493.00 8493.0 USD
PORTABLE RM100 VISCOMETER IN CARRYING CASE
Includes:
• Integrated temperature probe
• Carrying case
• Touch screen stylus
• Calibration and checking certificate
• Microfiber cloth
• Harness
• User manual

FEATURES: Autonomy more than one hour • Charge indicator • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed • Usable with standard or rack stand (option)

REGULAR PRICE: $8,301.00
8,301.00 8301.0 USD
Coulometric Karl Fischer Titrator
-Measuring Range; Water content / Bromine index: 10ug to 300mg
-Measurement cell; 2-Component or 1-Component
-Precision; Relative standard deviation : less than 0.3% (n=10) *Per KEM standard measurement conditions and standard liquids
-Display resolution; 0.1ug
-Methods; 20
-Data storage; 100 samples
-External I/O; -232C port × 2 (for printer, balance, software), USBx1 (for USB flash drive, printer, keyboard, barcode reader, foot switch, USB hub, Android device)
-Ambient Condition; (1) Temperature: 5 to 35°C (2): 85% H or below (no condensation)
-Power Source; AC100 - 240 ±10% 50/60 Hz
-Dimensions; 141(W ) × 292(D) × 244(H) mm
-Weight; Approx.3.0kg
-GLP Conformance; Registration of operator / Check performance with standard substance / reagent life control / Management of conduction time
-Conformity Standard; CE marking EMC: EN61326-1 L D: EN61010-1
8,075.00 8075.0 USD
Volumetric Karl Fischer Titrator
MKV-710B Volumetric Karl Fisher Titrator

Specifications:
-Type: Volumetric Karl Fischer Moisture Titrator

-Model: MKV-710B

-Product configuration: MKV-710+ Manual Solvent Change Unit.

-Measuring method: Karl Fischer Volumetric Titration

-Measuring range:
1. Water content: 0.1 to 500mgH2O (depends on KF reagent factor)
2. 10ppm to 100%H2O

-Burette precision: Volume: 10mL burette, Discharge precision: ±0.015mL repeatability, Repeatability: ±0.005mL

-Endpoint detection: By polarized potential level detected with a twin platinum electrode

-Titration form: Normal titration / Back titration (Option additional burette required)

-Required solvent: 30 to100mL (in S-type titration vessel)

-Methods: 20

-Key Operation: Sheet key on main unit

-Display:
1. White LED-backlit LCD
2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish
3. 1-channel display

-Calculation: Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value

-Data storage: 100 samples

-GLP conformance: 􏰄registration of operator / 􏰅Record of check results/ Record of factor measurement / Management of conduction time

-External I/O:
1. RS232C port × 2 (for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP)
2. USB x 1 (for USB flash drive, thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB, Android device)
3. SS-BUS x 1 (for APB)

-Extensibility
1. Automatic piston burette: Can control max 2 burette drives (including two built-in burette drives)

-Ambient Condition:
1. Temperature; 5 to 35°C
2. Humidity; 85%RH or below (no condensation)

-Power Source: AC100 - 240 ±10% 50/60 Hz

-Power Consumption: Main unit; Approx. 20W, Printer; Approx. 7W

-Dimensions:
1. Titration Unit; 141(W) × 292(D) × 367(H) mm (, not incl. tubing)
2. Stirrer; 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
3. Solvent Change Unit; 240(W) × 140(D) × 400(H) mm (not incl. tubing)
4. Printer; 106(W)× 180(D) × 88(H) mm

-Weight:
1. Titration Unit = 4.0kg,
2. Stirrer = 2.0kg,
3. Solvent Change Unit = 0.6kg,
4. Printer = 0.4kg

-Conformity Standard: CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
7,850.00 7850.0 USD
High-temperature probe for QTM-700 series
PD-31N High-temperature probe for QTM 700 series

Thermal conductivity is measured by "sandwiching" the sample material between the heater and the temperature sensor. The PD-31N is a conventional type of sensor but with additional capabilities to allow the measurement of thermal conductivity with higher temperature ranges.
-New Materials
-Firebrick
-Heat insulation materials

-Optional high-temperature probe; #K1206479 / PD-31N High-temperature probe
>Measurement range: 0.06 ~ 5W/(m K)
>Dimensions: 110(w) x 50(d) x 100 (h) mm
>Measurment tempeature: -100 ~ 1,000 degree C
>Measuremnt time: 60 seconds
>Sample size: 100x50x20 mm or more 2 pieces

5,585.00 5585.0 USD