Karl Fischer Titration
Automatic Titrators
Surface Science
Density Meters
Viscosity
Particle Size
Contact Us
0
0
Sign in
Contact Us
Show categories
Categories
All Products
Moisture
Karl Fischer
Titrators
Aquapal
MKC-710
MKV-710
Parts & Accessories
Aquapal
KEM 500/600
KEM 710
Reagents
Coulometric
Volumetric
Water Standards
Evaporators
Water Activity
Loss on Drying
Automatic Titration
Titrators
Electrodes
Sample Changers
Parts & Accessories
KEM 500/600
KEM 710
Surface Science & Analysis
Automatic Tensiometers
Manual Tensiometers
DuNouy Rings
Wilhelmy Plates
Tensiometer Accessories
Contact Angle Meters
Liquid Density
Density Meters
Density Standards
Parts & Accessories
Refractometer & Brix
Benchtop Refractometers
In-Line Refractometers
Handheld Refractometers
Salt Refractometers
Refractometer Standards
Thermal
Thermal Conductivity
Heat Flow
WBGT
FeverWarn
Liquid properties
Consistency
Viscosity
Analytical Reference Standards
Particle Size
Products
Moisture
SG Webstore
Sort By:
Featured
Price - Low to High
Price - High to Low
Newest arrivals
Name
Zeolite tube
$
15.25
$
15.25
15.25
USD
K430-0053: Zeolite tube
Zeolite Tube
$
18.67
$
18.67
18.67
USD
K12-01260-01:K12-01260-01; Zeolite Tube
Zeolite (500g) (Molecular Sieves 04174-75)
$
89.26
$
89.26
89.26
USD
61-00258; Zeolite (98-810-3412)
Waste bottle stand
$
215.07
$
215.07
215.07
USD
K433-0018: Waste bottle stand
Waste bottle cover
$
59.74
$
59.74
59.74
USD
K433-0021: Waste bottle cover
Waste bottle
$
93.19
$
93.19
93.19
USD
K433-0083: Waste bottle
Waste Liquid Bottle (500mL)
$
126.00
$
126.00
126.0
USD
K120440301: K120440301; Waste Liquid Bottle (500mL)
Washing bottle
$
18.64
$
18.64
18.64
USD
K1204251 (K500-3134): Washing bottle
Warming tube
$
661.00
$
661.00
661.0
USD
K1202700 (K433-0015): The warming tube delivers the moisture from the evaporator to the titration cell. The heated tube helps to prevent condensation and moisture interference during delivery of moisture.
Ware Washer
$
2.00
$
2.00
2.0
USD
Ware Washer
Volumetric Karl Fischer Titrator
$
7,850.00
$
7,850.00
7850.0
USD
MKV-710B Volumetric Karl Fisher Titrator
Specifications:
-Type: Volumetric Karl Fischer Moisture Titrator
-Model: MKV-710B
-Product configuration: MKV-710+ Manual Solvent Change Unit.
-Measuring method: Karl Fischer Volumetric Titration
-Measuring range:
1. Water content: 0.1 to 500mgH2O (depends on KF reagent factor)
2. 10ppm to 100%H2O
-Burette precision: Volume: 10mL burette, Discharge precision: ±0.015mL repeatability, Repeatability: ±0.005mL
-Endpoint detection: By polarized potential level detected with a twin platinum electrode
-Titration form: Normal titration / Back titration (Option additional burette required)
-Required solvent: 30 to100mL (in S-type titration vessel)
-Methods: 20
-Key Operation: Sheet key on main unit
-Display:
1. White LED-backlit LCD
2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish
3. 1-channel display
-Calculation: Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value
-Data storage: 100 samples
-GLP conformance: registration of operator / Record of check results/ Record of factor measurement / Management of conduction time
-External I/O:
1. RS232C port × 2 (for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP)
2. USB x 1 (for USB flash drive, thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB, Android device)
3. SS-BUS x 1 (for APB)
-Extensibility
1. Automatic piston burette: Can control max 2 burette drives (including two built-in burette drives)
-Ambient Condition:
1. Temperature; 5 to 35°C
2. Humidity; 85%RH or below (no condensation)
-Power Source: AC100 - 240 ±10% 50/60 Hz
-Power Consumption: Main unit; Approx. 20W, Printer; Approx. 7W
-Dimensions:
1. Titration Unit; 141(W) × 292(D) × 367(H) mm (, not incl. tubing)
2. Stirrer; 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
3. Solvent Change Unit; 240(W) × 140(D) × 400(H) mm (not incl. tubing)
4. Printer; 106(W)× 180(D) × 88(H) mm
-Weight:
1. Titration Unit = 4.0kg,
2. Stirrer = 2.0kg,
3. Solvent Change Unit = 0.6kg,
4. Printer = 0.4kg
-Conformity Standard: CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
Viscous sampler
$
322.61
$
322.61
322.61
USD
K740-3030: Viscous sampler
Vapor proof cover for 18 samples
$
716.89
$
716.89
716.89
USD
K710-148: Vapor proof cover for 18 samples
Vapor proof cover for 12 samples
$
716.89
$
716.89
716.89
USD
K710-048: Vapor proof cover for 12 samples
USB Serial Transducer US232R-10
$
97.00
$
97.00
97.0
USD
640017700; USB Serial Transducer US232R-10; converts RS232 to USB
USB Cable (A-A) 0.9m for connecting MCU with add'l titrators
$
21.00
$
21.00
21.0
USD
K640064333; USB Cable (A-A) 0.9m for connecting MCU with add'l titrators
Twin platinum electrode for Volumetric Karl Fischer Titrator
$
505.00
$
505.00
505.0
USD
K12-03755-01 (K103-M714): Twin platinum electrode. Volumetric Karl Fischer Detector Electrode
Twin platinum detector electrode (coulometric)
$
520.00
$
520.00
520.0
USD
K1203755 (K103-M713): Twin platinum electrode - Coulometric Karl Fischer Detector Electrode
Twin Platinum Electrode For Mks-210
$
518.52
$
518.52
518.52
USD
K103-M711:Twin Platinum Electrode For Mks-210
Tube, gas purge
$
7.17
$
7.17
7.17
USD
K521-0045: Tube