• Titrators
  • Electrodes
  • Sample Changers
  • Parts & Accessories
Turntable (12 vials) for CHA600
K12-001-3800-48:Turntable (12 vials) for CHA600
535.00 535.0 USD
Electrode Holder (multi for CHA600 Sample Changer)
K12-001-6500-48:Electrode Holder (multi for CHA600 Sample Changer)
190.00 190.0 USD
Electrode Auto Cleaning Bath Unit (for 6 samples)
K1204267: This automatic shower is an additional accessory that can be used to improve the traditional dip rinse used to clean the electrode between samples. This shower is for aqueous samples only. There is an additional shower configuration for non-aqueous samples.

Electrode Auto-Cleaning Bath Assy. for 6-place unit
consists of:
1 ea Cleaning Bath with tubing and clamp
1 ea Pump Unit
1 ea Cleaning Solution Tube
1 ea TPO tube + PTFE tube 1.5m
1 ea Overflow tube
1 ea 12-04408 10L Polyethylene Container
4 ea Hose Clamp
1 ea Clip
1,950.00 1950.0 USD
Electrode Auto Cleaning Bath Unit (for 11 samples)
K120426701; This automatic shower is an additional accessory that can be used to improve the traditional dip rinse used to clean the electrode between samples. This shower is for aqueous samples only. There is an additional shower configuration for non-aqueous samples.

Electrode Auto-Cleaning Bath Assy. for 11-place unit
consists of:
1 ea Cleaning Bath with tubing and clamp
1 ea Pump Unit
1 ea Cleaning Solution Tube
1 ea TPO tube + PTFE tube 1.5m
1 ea Overflow tube
1 ea 12-04408 10L Polyethylene Container
4 ea Hose Clamp
1 ea Clip
1,994.00 1994.0 USD
6 Position Sample Changer
CHA-700 : Automatic Titrator Multiple Sample Changer

1)Compact Design; This changer can be placed on top of the AT-700/710. You will see how compact it is: equipment width – 365mm.
2)Six-rack Model or Eleven-rack Model; Six racks for samples plus one more rack for immersion cleaning. Holds beakers of 250mL or 200mL.
Eleven-rack model: Holds containers of φ46mm, such as 50mL beakers or 100mL disposable cups.
3) Optional Electrode Cleaning Available; Optional electrode cleaning system can be connected for shower cleaning of electrodes. Furthermore, for six-rack model, shower cleaning (nonaqueous) of electrodes and drain samples from the beaker is available.
4) Different Measurement Methods from One Rack to Another; Individual settings can be made for each rack, which enables you to easily perform measurements of several different
samples.

-Sample Container options; 250mL beaker, 200mL disposable cup, 250mL beaker or 200mL beaker. Additional options include;
100mL disposable cup, 50mL beaker, 100mL beaker or 100mL tall beaker
-Cleaning; Dipping in beaker at fixed position / Shower cleaning (option)
-Rinse Solution; Pure water , alcohol, etc.
-Stirring Device; Propeller stirrer
-Sequence setting; Set from Automatic Potentiometric Titrator
-Sequence control; 1)Auto : started by Automatic Potentiometric Titrator / 2)Manual : operated from Automatic Potentiometric Titrator
-Power Supply; DC24V 1.9A(Main unit) AC100-240V 10% 50/60 Hz(Comes with AC Adapter)
-Dimensions; 365 (W) × 443(D) × 315 (H) mm
-Weight; Approx. 8kg
-CE Marking; EMC : EN61326 / LVD : Conforming to EN61010-1
8,500.00 8500.0 USD
11 Position Sample Changer
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
9,900.00 9900.0 USD