KEM AT-710B Automatic Potentiometric Titrator with Standard Preamp.
Specifications
Type: Automatic Potentiometric Titrator
Model: AT710B
Product configuration: AT710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)
Detection range:
1) Potentiometric : 2000mV to +2000mV
2) pH : 20.000 to 20.00pH
3) Temperature : 0 to 100°C
Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
Method: Standard method 20. (Max 2 methods can be linked)
Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity
Titration form: Full titration (Auto EP detection), EP Stop, Level Stop
Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)
Key operation: Sheet Key on the main unit
Displays:
1) White LEDbacklit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1channel display
Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value
Data Storage: 50 samples
GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time
Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL
Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL
External I/O:
RS232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFTCAP)
SSBUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device
Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
builtin burette drives)
Multiple sample changer: CHA700 series
Ambient condition:
1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)
Power source: AC100 240V ±10% 50/60 Hz
Power consumption: 20W
Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm
Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg
Conformity standard: CE marking EMC: EN613261 LVD: EN610101 RE