Skip to Content
Hydranal Composite 1, Case of 6x1L bottles
CC34827 6x1L; A reagent for Volumetric Karl Fischer titrators. Hydranal Composite 1 is a one-component reagent. General one-component reagent 1mL=approx. 0.7-1.0mg H2O
1,098.17 1098.17 USD
Hydranal Composite 2, 500mL bottle
CC34806 - 500mL; A reagent for Volumetric Karl Fischer titrators. Hydranal Composite 2 is a one-component reagent. General one-component reagent 1mL=approx. 2.0mg H2O
133.31 133.31 USD
Hydranal Comp 5K, 2.5 Liter bottle
CC34816-2.5L; A reagent for Volumetric Karl Fischer titrators. Hydranal Comp. 5K is designed to work with samples containing ketones & aldehydes.. (1 mL=appox. 5.0 mg H20)
642.41 642.41 USD
Hydranal Comp 5, 2.5 Liter bottle
CC34805-2.5L; A reagent for Volumetric Karl Fischer titrators. Hydranal Composite 5 is a one-component reagent. General one-component reagent 1mL=approx. 5.0mg H2O (This is one of the most popular volumetric reagents used!)
414.36 414.36 USD
Hydranal Comp 2, 1Liter bottle
CC34806-1L; A reagent for Volumetric Karl Fischer titrators. Hydranal Composite 2 is a one-component reagent. General one-component reagent 1mL=approx. 2.0mg H2O
190.99 190.99 USD
Hydranal Comp 1, 1Liter bottle
CC34827-1L; A reagent for Volumetric Karl Fischer titrators. Hydranal Composite 1 is a one-component reagent. General one-component reagent 1mL=approx. 0.7-1.0mg H2O
210.10 210.1 USD
Evaporator (KF-610 series)
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
8,800.00 8800.0 USD
EBU-710-KF Burette Unit
Swappable KF burette (10mL) Unit for volumetric Karl Fischer Titrator MKV-710
1,495.00 1495.0 USD
EBU-710-20 Burette Unit (20mL)
EBU-710-20B Burette Unit for Automatic Titrator
940.00 940.0 USD
EBU-710-05B Burette Unit (5mL)
Swappable 5mL burette Unit for automatic AT-710 Titrator
925.00 925.0 USD
EBU-610-20B (20mL)
EBU-610-20B Burette Unit (20mL) for Automatic Titrator; AT-500 and AT-600 series (KEM)
925.00 925.0 USD
Cylinder with piston head 20mL
Cylinder with piston head 20mL. For AT600 series automatic titrators
(also for the 500 series)
437.00 437.0 USD
Cylinder with piston 10mL
K12-006-5200-48 (K430-0048):Cylinder with piston 10mL for MKA500/600 series volumetric titrator
475.00 475.0 USD
Coulometric Karl Fischer Titrator
-Measuring Range; Water content / Bromine index: 10ug to 300mg
-Measurement cell; 2-Component or 1-Component
-Precision; Relative standard deviation : less than 0.3% (n=10) *Per KEM standard measurement conditions and standard liquids
-Display resolution; 0.1ug
-Methods; 20
-Data storage; 100 samples
-External I/O; -232C port × 2 (for printer, balance, software), USBx1 (for USB flash drive, printer, keyboard, barcode reader, foot switch, USB hub, Android device)
-Ambient Condition; (1) Temperature: 5 to 35°C (2): 85% H or below (no condensation)
-Power Source; AC100 - 240 ±10% 50/60 Hz
-Dimensions; 141(W ) × 292(D) × 244(H) mm
-Weight; Approx.3.0kg
-GLP Conformance; Registration of operator / Check performance with standard substance / reagent life control / Management of conduction time
-Conformity Standard; CE marking EMC: EN61326-1 L D: EN61010-1
8,075.00 8075.0 USD
Burette Unit (5mL)
EBU-610-05B Burette Unit for Automatic Titrator
850.00 850.0 USD
Burette Unit (50mL)
EBU-610-50B Burette Unit for Automatic Titrator
1,333.00 1333.0 USD
Burette Unit (1mL)
EBU-610-01B Burette Unit for Automatic Titrator
1,275.00 1275.0 USD
Burette Unit (10mL) for Karl Fisher
EBU-610-KF Burette Unit for Karl Fischer Titrator
1,275.00 1275.0 USD
Burette Unit (10mL)
EBU-610-10B Burette Unit for Automatic Titrator
850.00 850.0 USD
Automatic Titrator (with standard preamp)
KEM AT­-710B Automatic Potentiometric Titrator with Standard Preamp.

Specifications
­Type: Automatic Potentiometric Titrator

­Model: AT­710B

­Product configuration: AT­710 w/standard preamp, w/Magnetic stirrer
(combined pH electrode and temperature compensation electrode included)

­Detection range:
1) Potentiometric : ­2000mV to +2000mV
2) pH : ­20.000 to 20.00pH
3) Temperature : 0 to 100°C

­Titration mode: Auto Titration, Auto Intermit, Intermit, Stat
­Method: Standard method 20. (Max 2 methods can be linked)

­Kinds of titration: Potentiometric (acid/base, redox, precipitation), Photometric,
Polarization, Conductivity

­Titration form: Full titration (Auto EP detection), EP Stop, Level Stop

­Special application: Measurement of electrode potential (pH, potential), Acid
dissociation constant (pKa)

­Key operation: Sheet Key on the main unit

­Displays:
1) White LED­backlit LCD
2) English / Japanese / Mandarin Chinese /Korean / Russian / Spanish
3) 1­channel display

­Calculation: Concentration of content, statistics data processing (mean, SD
and RSD) and automatic averaging of blank and factor value

­Data Storage: 50 samples

­GLP conformance: Registration of operator / Record of check results / Record
of electrode calibration / Verification of burette capacity / Management of
conduction time

­Burette size: 20mL glass burette with brown cover (Standard) Optional burette
units: 10mL, 5mL, or 1mL

­Burette accuracy:
50mL burette(Auto dispenser) ± 0.5mL,
20mL burette ± 0.02mL reproducibility ± 0.01mL
10mL burette ± 0.015mL reproducibility ± 0.005mL
5mL burette ± 0.01mL reproducibility ± 0.003mL
1mL burette ± 0.005mL ; reproducibility ± 0.001mL

­External I/O:
RS­232 port x 2: for Dot matrix printer, Electronic balance, Data Capture
Software (SOFT­CAP)
SS­BUS × 1: for Multiple sample changer, APB
ELE. × 1: for Smart electrode
TEMP.COMP. × 1: an Input terminal for the temperature sensor to correct reagent
volume, sensor Pt100, temperature reading accuracy: ±0.5°C (burette 1 only)
USB × 1: for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot
switch, USB HUB, Android device

­Extensibility:
Automatic piston burette: Can control max 10 burette drives (Including two
built­in burette drives)
Multiple sample changer: CHA­700 series

­Ambient condition:

1) Temperature: 5 to 35°C
2) Humidity: 85%RH or below (no condensation)

­Power source: AC100 ­ 240V ±10% 50/60 Hz
­Power consumption: 20W

­Dimensions:
Titration unit: 141(W) × 296(D) × 367(H)mm
Printer: 106(W) × 180(D) × 88(H) mm

­Weight:
Titration unit: Approx. 4.0kg
Printer : Approx. 0.4kg

­Conformity standard: CE marking EMC: EN61326­1 LVD: EN61010­1 RE
Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
8,500.00 8500.0 USD