Skip to Content
Automatic Piston Burette
APB-620; Automatic Piston Burette for Auto Titrator
5,152.00 5152.0 USD
Automatic Piston Burette, 20mL
APB-610; Automatic Piston Burette for Auto Titrator; 20mL
3,875.00 3875.0 USD
Aquapal III Moisture Analyzer w/ Standard Glassware
Aquapal III Moisture Analyzer W/ Standard Glassware:
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved Manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm -% - ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
8,080.00 8080.0 USD
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
Aquapal III Moisture Analyzer W/ Single Reagent Glassware: Coulometric Titrator Diaphramless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved Manufacturer. unit ready for operation, includes: - Built in printer with standard paper that backs up test with hard copy results. - Speed is 2 mg/minute - Test range from 1ppm to 100% - Sensitive to 0.1 ug - Calculations in Weight, volume or dilution - Automatic Drift Correction - Results printed in ppm ,% , ug - Standard RS232C output - Small lab foot print 14" x 8" - Portable (field Use) *Easy to use for non-technical operators - Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will printout automatically.
8,080.00 8080.0 USD
6 Position Sample Changer
CHA-700 : Automatic Titrator Multiple Sample Changer

1)Compact Design; This changer can be placed on top of the AT-700/710. You will see how compact it is: equipment width – 365mm.
2)Six-rack Model or Eleven-rack Model; Six racks for samples plus one more rack for immersion cleaning. Holds beakers of 250mL or 200mL.
Eleven-rack model: Holds containers of φ46mm, such as 50mL beakers or 100mL disposable cups.
3) Optional Electrode Cleaning Available; Optional electrode cleaning system can be connected for shower cleaning of electrodes. Furthermore, for six-rack model, shower cleaning (nonaqueous) of electrodes and drain samples from the beaker is available.
4) Different Measurement Methods from One Rack to Another; Individual settings can be made for each rack, which enables you to easily perform measurements of several different
samples.

-Sample Container options; 250mL beaker, 200mL disposable cup, 250mL beaker or 200mL beaker. Additional options include;
100mL disposable cup, 50mL beaker, 100mL beaker or 100mL tall beaker
-Cleaning; Dipping in beaker at fixed position / Shower cleaning (option)
-Rinse Solution; Pure water , alcohol, etc.
-Stirring Device; Propeller stirrer
-Sequence setting; Set from Automatic Potentiometric Titrator
-Sequence control; 1)Auto : started by Automatic Potentiometric Titrator / 2)Manual : operated from Automatic Potentiometric Titrator
-Power Supply; DC24V 1.9A(Main unit) AC100-240V 10% 50/60 Hz(Comes with AC Adapter)
-Dimensions; 365 (W) × 443(D) × 315 (H) mm
-Weight; Approx. 8kg
-CE Marking; EMC : EN61326 / LVD : Conforming to EN61010-1
8,500.00 8500.0 USD
11 Position Sample Changer
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
9,900.00 9900.0 USD
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
Coulometric Titrator Diaphragmless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved manufacturer.
Unit ready for operation. Includes:
- Built in printer with standard paper that backs up test with hard copy results.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm ,% , ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
- Easy to use for non-technical operators
- Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will print out automatically.
8,493.00 8493.0 USD
Aquapal III Moisture Analyzer w/ Standard Glassware
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1ug
- Calculations in weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm, %, ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field use)
8,493.00 8493.0 USD
Aquapal III Karl Fischer Moisture Analyzer (no Glassware)
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved manufacturer.
Unit ready for operation. Includes:
- Built in printer with standard paper that backs up test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm, %, ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
5,250.00 5250.0 USD
Hydranal Formamide Dry, 1Liter bottle
CC34724 -1L; A co-solvent for Volumetric Karl Fischer titrators. Add this co-solvent to either one-component solvents (Methanol Dry or Methanol Rapid) or two-component solvents (Hydranol Solvent) to improve solubility. Formamide improves the solubility of polar substances in methanol and is therefore prefered for the determination of water in carbohydrates, proteins, and inorganic salts. Formamide also accelerates the extraction of moisture from solids and is used in the titration of starch and other foodstuffs and naturally occurring substances, as well as in titrations as elevated temperatures. Formamide should not be used at concentrations >50% by volume.
148.53 148.53 USD