Skip to Content
Hydranal Coulomat AG-H, 500ml
Anolyte. Coulometric analysis for cells with or without a diaphragm. Hydranal anolytes contain iodide and a sulphur dioxide/imidazole buffer in a suitable solvent. Effective for very polar samples (long-chained hydrocarbons). Free of carbon tetrachloride and chloraform.
Shelf life is 5 years, as long as the bottle remains unopened.
225.00 225.0 USD
Hydranal Coulomat CG, 50ml (10x5ml ampoules) x6
Standard catholyte for coulometry cells with a diaphram. It contains protected ammonium salts as the reactive component and methanol. 5ml ampules.
Shelf life is 5 years, as long as the bottle remains unopened.
843.00 843.0 USD
Hydranal Coulomat CG, 50ml (10x5ml ampoules)
Standard catholyte for coulometry cells with a diaphram. It contains protected ammonium salts as the reactive component and methanol. Ten 5ml ampules.
Shelf life is 5 years, as long as the bottle remains unopened.
161.00 161.0 USD
Hydranal Water Standard 1.00 (10 x 4ml ampoules)
CERTIFIED STANDARD containing 1.00mg of H2O per gram (1mg/g = 0.1%). A manufacturer's test certificate with exact specifications is included. Total of 40ml, packaged as ten 4ml ampoules.
198.00 198.0 USD
Hydranal Coulomat CG-K, 50ml
SPECIALTY REAGENT FOR ALDEHYDES & KEYTONES. Catholyte for coulometric water determination in samples of aldehydes & keytones. Packaged as 10x5ml ampules
404.00 404.0 USD
Hydranal Coulomat Ak, 500ml
SPECIALTY REAGENT FOR ALDEHYDES & KEYTONES. Anolyte for coulometric water determination in samples containing keytones.
457.00 457.0 USD
Hydranal Coulomat A, 500ml x6
Anolyte standard two component coulometry. Hydranal anolytes contain iodide and a sulphur dioxide/imidazole buffer in a suitable solvent. Coulomat A contains methanol and chloroform as the solvents. Water capacity is > 10mg/ml.
Shelf life is 5 years, as long as the bottle remains unopened.
1,010.00 1010.0 USD
Hydranal Coulomat A, 500ml
Anolyte standard two component coulometry. Hydranal anolytes contain iodide and a sulphur dioxide/imidazole buffer in a suitable solvent. Coulomat A contains methanol and chloroform as the solvents. Water capacity is > 10mg/ml.
Shelf life is 5 years, as long as the bottle remains unopened.
197.00 197.0 USD
VISCO-RM Software
Software for: First RM, RM 100, RM 100i, RM 100L
1,815.00 1815.0 USD
RM 200 PLUS RHEOMETER WITH STANDARD STAND
INCLUDES:
• Integrated temperature probe
• Standard stand
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: • Ramp programming • Direct analysis with regressions • Direct control of temperature unit • Speed or shear rate control • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed
12,321.79 12321.79 USD
PORTABLE RM 100 VISCOMETER IN CARRYING CASE WITHOUT SPINDLE
Includes:
• Integrated temperature probe
• Carrying case
• Touch screen stylus
• Calibration and checking certificate
• Microfiber cloth
• Harness
• User manual

FEATURES: Autonomy more than one hour • Charge indicator • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed • Usable with standard or rack stand (option)
9,508.57 9508.57 USD
RM 100 PLUS VISCOMETER WITH STANDARD STAND
INCLUDES:
• Integrated temperature probe
• Standard stand
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Speed or shear rate control • Direct control of temperature unit • Programming and recording method • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Printer connection • Compatible with RheoTex software • Display of viscosity limits according to spindle and speed
8,037.99 8037.99 USD
First Plus Viscometer with Standard Stand
INCLUDES:
• Integrated temperature probe
• Standard stand
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Integrated temperature probe • Printer connection • Display of viscosity limits according to spindle and speed
6,224.75 6224.75 USD
B-ONE PLUS VISCOMETER WITH RV-2 TO R-7 SPINDLES SET AND STANDARD STAND
INCLUDES:
• 6 RV spindles
• Standard stand
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Display of viscosity limits according to spindle and speed

LIST PRICE: $5,042.00
5,330.17 5330.17 USD
PORTABLE B-ONE VISCOMETER IN CARRYING CASE WITHOUT SPINDLE
INCLUDES:
• Carrying case
• Touch screen stylus
• Calibration and checking certificate
• Microfiber cloth
• Harness
• User manual
FEATURES: Autonomy more than one hour • Charge indicator • Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Display of viscosity limits according to spindle and speed.
Shipping dimensions: 60 x 50 x 35 cm, 16 kg
5,628.35 5628.35 USD
B-ONE PLUS LR VISCOMETER WITH LV-1 TO LV-4 SPINDLES SET AND STANDARD STAND
INCLUDES:
• 4 LV Spindles
• Standard stand
• Touch screen stylus
• User manual
• Calibration and checking certificate
• Microfiber cloth

FEATURES: Direct measure with time to stop • User and locked mode • Data recording and USB transfer • Torque gauge on display • Display of viscosity limits according to spindle and speed
5,279.59 5279.59 USD
Automatic Surface Tensiometer, DyneMaster DY-300
This instrument is specified for determining interfacial tension of oil against water by the ring method in ASTM Method D971 and solutionsof surface-active agents in ASTM Method D1331. It is also specified for testing synthetic rubber lattices in ASTM Method D1417 and determing the surface tension of industrial water and industrial wastewater in ASTM Method D1590 (To name a few).

Main unit (laptop PC not included), software provided on CD, Platinum plates or DuNouy Ring (choose 2), Glass lab dishes for surface tension (x2), Calibration weights (200mg x2), built in Level, Alcohol lamp, Forceps, and operation manual.

Features:
◆ ­Fully automatic operation by single command button
◆ For QC use, repetition of measurement can be preset
­◆ For surface solutions, graph of variations over time can be plotted
­◆ For R&D use, functions of graph overwriting and data converting to a spreadsheet can be prepared
­◆ Measurements of lamella length and liquid density are available in addition to surface/interfacial tension

Screens:
• ­Surface Tension (static mode)
­• Surface Tension (dynamic variations over time)
­• Surface Tension (high viscous material)
­• Lamella Length

Applications:
• ­Surface Tension: evaluating detergency of detergents, wettability of coating agents
­• Interfacial Tension: evaluating emulsification property of water/oil
­• Lamella Length: evaluating foaming stability of coating agents
• Liquid Density: measuring density of liquids

Specifications:
• Measurement Method: Wilhelmy Plate method and or DuNouy Ring method
­• Measurement Range: 0~100 mN/m *Balance capacity and displaying range 0~1000 mN/m
• ­Measurement Accuracy: 0.2 mN/m
­• Resolution: 0.01 mN/m
• ­Stage Speed: 0.1~1 mm/s
­• Measurement Temperature: Ambient~150 degrees C (Heater type stage system)10~70 degrees C (Jacket type stage set with hot/cold water circulator 4VT)
• Software: Standard: Surface/Interfacial tension, Lamella length, Liquid density
• Detecting Parts: Standard: Platinum plate
• Option: Platinum ring, Pycnometer for density, Accessory for sedimentation
­• External Dimensions: 255(W)x307(D)x369(H) mm
• ­Weight: about 12.5kg
­• Electric power: AC100­240~50/60Hz 35W 75VA
17,200.00 17200.0 USD
Automatic Surface Tensiometer, DyneMaster DY-300, with Computer
This instrument is specified for determining interfacial tension of oil against water by the ring method in ASTM Method D971 and solutionsof surface-active agents in ASTM Method D1331. It is also specified for testing synthetic rubber lattices in ASTM Method D1417 and determing the surface tension of industrial water and industrial wastewater in ASTM Method D1590 (To name a few).

Main unit, Laptop PC, software provided on CD, Platinum plate or DuNouy Ring (choose 2), Glass lab dishes for surface tension (x2), Calibration weights (200mg x2), built in Level, Alcohol lamp, Forceps, and operation manual.

Features:
◆ ­Fully automatic operation by single command button
­◆ ­For QC use, repetition of measurement can be preset
­◆ ­For surface solutions, graph of variations over time can be plotted
­◆ ­For R&D use, functions of graph overwriting and data converting to a spreadsheet can be prepared
◆ ­­Measurements of lamella length and liquid density are available in addition to surface/interfacial tension

Screens:
• ­Surface Tension (static mode)
• ­Surface Tension (dynamic variations over time)
­• ­Surface Tension (high viscous material)
­• ­Lamella Length

Applications:
• ­Surface Tension: evaluating detergency of detergents, wettability of coating agents
• ­-Interfacial Tension: evaluating emulsification property of water/oil
­• ­Lamella Length: evaluating foaming stability of coating agents
• ­Liquid Density: measuring density of liquids

Specifications:
­• ­Measurement Method: Wilhelmy Plate method and or DuNouy Ring method
­• ­Measurement Range: 0~100 mN/m *Balance capacity and displaying range 0~1000 mN/m
• ­­Measurement Accuracy: 0.2 mN/m
­• ­Resolution: 0.01 mN/m
• ­Stage Speed: 0.1~1 mm/s
­• ­Measurement Temperature: Ambient~150 degrees C (Heater type stage system)10~70 degrees C (Jacket type stage set with hot/cold water circulator 4VT)
­• ­Software: Standard: Surface/Interfacial tension, Lamella length, Liquid density
• ­Detecting Parts: Standard: Platinum plate
• ­Option: Platinum ring, Pycnometer for density, Accessory for sedimentation
­• ­External Dimensions: 255(W)x307(D)x369(H) mm
• ­Weight: about 12.5kg
­• ­Electric power: AC100­240~50/60Hz 35W 75VA
0.00 0.0 USD
Digital Tensiometer DST-30
For DuNouy Ring method.
Includes:
- Platinum-iridium ring
- Operation manual
- Tweezers
- Beaker
- Hook
- Power cable
- Calibration jig and weight
8,025.00 8025.0 USD
Alcohol Lamp For Cleaning Du Nouy Tensiometer Rings
Alcohol Lamp For Cleaning Du Nouy Tensiometer Rings.
65.60 65.6 USD